Cáp mạng AMP Commscope U/UTP, Cat.6, 4 đôi, CM, 24 AWG, Solid, màu trắng, 305m 427071-2
General Specifications
Regional Availability |
Asia |
Portfolio |
NETCONNECT® |
Product Type |
Twisted pair cable |
Dimensions
Product Number |
CS30CM |
ANSI/TIA Category |
6 |
Cable Component Type |
Horizontal |
Cable Type |
U/UTP (unshielded) |
Conductor Type,
singles |
Solid |
Conductors, quantity |
8 |
Jacket Color |
Blue |
Pairs, quantity |
4 |
Transmission Standards |
ANSI/TIA-568.2-D |
CENELEC EN 50288-6-1 | ISO/IEC 11801 Class E |
Cable Length |
304.800 m | 1000 ft |
Diameter Over
Insulated Conductor |
0.909 mm | 0.0358 in |
Diameter Over Jacket,
nominal |
5.410 mm | 0.213 in |
Conductor Gauge,
singles |
24 AWG |
Electrical
Specifications
Characteristic
Impedance |
100 ohm |
dc Resistance
Unbalance, maximum |
5 % |
dc Resistance, maximum |
9.38 ohms/100 m |
2.859 ohms/100 ft |
Delay Skew, maximum |
45 ns |
Dielectric Strength,
minimum |
1500 Vac | 2500 Vdc |
Mutual Capacitance at
Frequency |
5.6 nF/100 m @ 1 kHz |
Nominal Velocity of
Propagation (NVP) |
68 % |
Operating Frequency,
maximum |
250 MHz |
Operating Voltage,
maximum |
80 V |
Propagation Delay,
maximum |
536 ns/100m @250MHz |
Remote Powering |
Fully complies with
the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery
of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC
EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A |
Electrical Cable Performance
Frequency |
IL, STD |
NEXT, STD |
ACR, STD |
PSNEXT, STD |
PSACR, STD |
ACRF, STD |
PSACRF, STD |
RL, STD |
TCL, STD |
ELTCTL, STD |
1.00 MHz |
2.0 |
74.3 |
72.3 |
72.3 |
70.3 |
67.8 |
64.8 |
20.0 |
40.0 |
35.0 |
4.00 MHz |
3.8 |
65.3 |
61.5 |
63.3 |
59.5 |
55.8 |
52.8 |
23.0 |
40.0 |
23.0 |
8.00 MHz |
5.3 |
60.8 |
55.4 |
58.8 |
53.4 |
49.9 |
46.9 |
24.5 |
40.0 |
16.9 |
10.00 MHz |
6.0 |
59.3 |
53.3 |
57.3 |
51.3 |
47.8 |
44.8 |
25.0 |
40.0 |
15.0 |
16.00 MHz |
7.6 |
56.2 |
48.7 |
54.2 |
46.7 |
43.7 |
40.7 |
25.0 |
38.0 |
10.9 |
20.00 MHz |
8.5 |
54.8 |
46.3 |
52.8 |
44.3 |
41.8 |
38.8 |
25.0 |
37.0 |
9.0 |
25.00 MHz |
9.5 |
53.3 |
43.8 |
51.3 |
41.8 |
39.8 |
36.8 |
24.3 |
36.0 |
7.0 |
31.25 MHz |
10.7 |
51.9 |
41.2 |
49.9 |
39.2 |
37.9 |
34.9 |
23.6 |
35.1 |
|
62.50 MHz |
15.4 |
47.4 |
32.0 |
45.4 |
30.0 |
31.9 |
28.9 |
21.5 |
32.0 |
|
100.00 MHz |
19.8 |
44.3 |
24.5 |
42.3 |
22.5 |
27.8 |
24.8 |
20.1 |
30.0 |
|
155.00 MHz |
25.2 |
41.4 |
16.3 |
39.4 |
14.3 |
24.0 |
21.0 |
18.8 |
28.1 |
|
200.00 MHz |
29.0 |
39.8 |
10.8 |
37.8 |
8.8 |
21.8 |
18.8 |
18.0 |
27.0 |
|
250.00 MHz |
32.8 |
38.3 |
5.5 |
36.3 |
3.5 |
19.8 |
16.8 |
17.3 |
26.0 |
Material
Specifications
Conductor Material |
Bare copper |
Insulation Material |
Polyolefin |
Jacket Material |
PVC |
Minimum Bend Radius
Note |
4 times the outer
cable diameter |
Environmental
Specifications
Installation
temperature |
0 °C to +60 °C (-32 °F
to +140 °F) |
Operating Temperature |
-20 °C to +60 °C (-4
°F to +140 °F) |
Storage Temperature |
-20 °C to +80 °C (-4
°F to +176 °F) |
Environmental Space |
Non-plenum |
Flame Test Method |
CM | UL 1685 |
Packaging and Weights
Packaging Type |
Reel in box |
Regulatory
Compliance/Certifications
Agency |
Classification |
ROHS |
Compliant |
CHINA-ROHS |
Below maximum
concentration value |
REACH-SVHC |
Compliant as per SVHC
revision on www.commscope.com/ProductCompliance |
UK-ROHS |
Compliant |